- Written by ZILA GmbH
- font size decrease font size increase font size
Level measurement in open containers with our hydrostatic probes
Our probes convert pressure directly into an electronic standard signal in order to display the level in analogue form, e.g. in litres, m³, kg or %. We recommend the use of immersion probes especially for difficult mounting positions. For installation, it should be noted that the immersion probe is suspended from the top of the tank.
The screw-in probe must be fitted directly into the tank through a screw thread at the lowest point to be measured near the bottom.
Principle of our hydrostatic level gauge
The probes are available in stainless steel and ceramic versions. This means they can be used both in water and oily liquids, as well as in aggressive media. A membrane inside the measuring element is formed according to the pressure of the fluid column in the tank. Behind this, a piezoresistive silicon chip generates an output signal of 4...20 mA / 0...10V proportional to the atmospheric pressure via a built-in microcontroller.
Evaluation and display units
Our programmable digital display AD313, designed for panel mounting, offers a scaling function to display individual output values (litres etc.) as level-describing parameters. Moreover, adjustable limit values can be monitored by means of an alarm function as a relay output with this device. For this, you also need the top-hat rail evaluation units TK-313 or TK-315 to show the filling level in per cent. With the TK-313, two limit values can be monitored whilst with the TK-315 even four values can be observed using a relay output. The application described above is illustrated below.
Advantages of our hydrostatic level sensors
- Precise measurement, even with difficult tank or container designs
- High media compatibility
- Applicable even in combination with aggressive media
- High reliability along with a long service life
- Available as a complete system
- 4…20 mA output signal
- Excellent for level detection
A quick look at our product range for hydrostatic level measurement
Immersion probe - hanging version: HD-100 | HD-102 | HD-103
Measuring range: 0.8…10 mWs (other ranges available upon request)
Accuracy: <2% of final value
Housing: Stainless steel 1.4571 | PVC | PVDF
Measuring cell: Stainless steel 1.4404 | Ceramics 96% | Ceramics 99.9%
Supply voltage: 15…30 V DC
Output signal: 4…20 mA
Operating temperature: -10…70 °C (PVC -10…60°C)
Type: Hanging probe
Screw-in probes: HD-110 | HD-112 | HD-114
Measuring range: 0.8…10 mWs (other ranges available upon request)
Accuracy: <2% of final value
Housing: Stainless steel 1.4571 | PVC | PVDF
Measuring cell: Stainless steel 1.4404 | Ceramics 96% | Ceramics 99.9%
Supply voltage: 15…30 V DC
Output signal: 4…20 mA
Operating temperature: -10…70 °C (PVC -10…60°C)
Type: Screw-in probe
Programmable digital display: AD-310 | AD-313
Universal measuring inputs: Current 0…20 mA DC | Voltage 0…10 V DC | Potentiometric voltage divider 1...100 kΩ
Display: LED 14mm, 5-digit
Operation: Membrane keys
Display range: -19999…32000
Analogue output: 0…20 mA
Measuring inaccuracy: ±1 % or ±1 digit
Two programmable limit switches
Programmable relay function
Evaluation unit with two and four limit switches: TK-313 | TK-315
Operating temperature: -20…+60 °C
Nominal voltage: 24…230 V AC/DC
Input ssignal: Current 0…20 mA | Voltage 0…10 V | Resistor in three-wire circuit RG 0–4...10 kΩ
Output switch contacts: TK-313 two changeover contacts | TK-315 four changeover contacts
Switching voltage: max. 250 V AC
Fastening: Mounting rail according to EN 50022
Display: 2-digit, 7-segment