Menu

New protective caps for climate and dew point sensors

New protective caps for climate and dew point sensors

Climate and dew point sensors with new protective caps extend ZILA's application range Now, we can offer protective caps made of PTFE, aluminium or plastics for any of our compact (dew point) temperature and relative humidity sensors. This is the reason why exterior areas and environments with a higher damage potential are also included in the application range of our sensors now.

The protective cap, mounted on the upside of the sensor, protects its tip, depending on the application.

PTFE

for outdoor applications: Reliable humidity measurement with protection against penetrating water

white PTFE protective cap

Aluminium

for applications of high load: Extremely robust
for use on working machines and industrial plants

Aluminium protective cap

Plastics

for indoor applications: Standard plastic protective cap

grey protective cap

The robust rod design is the perfect solution for installation in corners, control cabinets or in boxes for climate monitoring. Other applications include mechanical and plant engineering, air conditioning in rooms and mobile areas as well as monitoring of storage rooms, containers or weather stations.

A small selection from our range of products includes:

KS-210/220

Analogue climate sensor KS-210 / KS-220 (temperature, relative humidity)

Climate sensor in rod design

  • Analogue climate sensor
  • Temperature / relative humidity
  • Length: 135 mm / Ø 19.2 mm
  • Measuring ranges: -40…+80 °C and …100 % relative humidity
  • Measuring accuracy: ± 0.2 K , ± 2 %
  • Signal outputs: 4…20 mA and 0…10 V
  • Operating voltage of the KS-210: 12...30 V DC
  • Operating voltage of the KS-220: 24 V DC
  • Operating temperatures: -40…+80 °C

TPS-210/220

TPS-210/220 (dew point temperature)

dewpoint sensor in rod design

  • Length: 135 mm / Ø 19.2 mm
  • Measuring ranges:-40…+80 °C (environment), 0…100 % rH, -50…+80 °C (dew point)
  • Measuring accuracy: ± 0.2 K , ± 2 %
  • Signal outputs: 4…20 mA and 0...10 V
  • Operating voltage of the TPS-210: 12…30 V DC
  • Operating voltage of the TPS-220: 24 V DC

KS-CAN-03

KS-CAN-03 (CAN bus climate sensor)

CAN-Bus Climate sensor in rod design

  • Length: 135 mm / Ø 19.2 mm
  • Measuring ranges: 40…+80 °C, …100 % relative humidity
  • Measuring accuracy: ± 0.5 K , ± 2 % (10…90 % rH)
  • Signal output: CANopen 2.0 A
  • Operating voltage: 10…48 V DC
  • Settling times: ≤ 4 s (rH) and ≤ 20s (T)

TSL-CAN-03

TSL-CAN-03 (CAN bus temperature sensor)

CAN-Bus temperature sensor in rod design

  • Length: 135 mm / Ø 19.2 mm
  • Measuring range: 40…+80 °C
  • Measuring accuracy: ± 0.3 K (10…+80°C)
  • Signal output: CANopen 2.0 A
  • Operating voltage: 10…48 V DC
  • Minimum air velocity required for measurement across the sensor: 1.5 m/s

Last modified onTuesday, 23 March 2021 15:15